An extinguisher that is not where it should be, is the wrong type or has not been inspected gives a false sense of security. It is usually one of the first things checked in an audit or inspection, and in an incipient fire it decides whether the fire is controlled in time.
What NOM-002-STPS-2010 sets out
Mexico's NOM-002-STPS-2010, on safety conditions for fire prevention and protection in workplaces, asks the employer, in general terms, to know the fire risk level of the facilities, have suitable fire-fighting equipment, mark it with signage, inspect and maintain it, train personnel and run drills. Always consult the current text of the standard: this article is a practical guide and does not replace reading it.
1. Know your risk and your fire classes
The type and number of extinguishers depend on the workplace's fire risk and the materials handled. As a general rule, four common fire classes are identified:
- Class A: combustible solids such as wood, paper, cardboard or textiles.
- Class B: flammable liquids and gases, such as solvents, fuels and paints.
- Class C: energized electrical equipment.
- Class D: combustible metals, which require specific agents.
A cardboard warehouse, a switchgear room and a solvent area do not need the same thing. Choosing the extinguishing agent without considering the material can be ineffective or even dangerous, for example using water on energized equipment.
2. Placement and signage
- Visible, accessible and unobstructed: no racks, pallets or boxes in front.
- Distributed so that no one has to travel an excessive distance; the standard sets the criteria according to risk level.
- Securely mounted and marked with a sign showing their location.
- Close to the highest-risk areas, without being blocked by the fire itself.
3. Inspection and maintenance
Fire-fighting equipment needs follow-up. As a general practice, carry out a periodic visual check with a record (seal intact, gauge in range, no dents, corrosion or damaged hoses) and maintenance by qualified personnel at the frequency set by the standard and the manufacturer. An extinguisher that has been used, even partially, must be recharged or replaced. Record the date and the person responsible: that is the evidence you are asked for in an inspection.
4. People: training, brigades and drills
Equipment is useless if no one knows how to use it. Train staff in extinguisher use and evacuation routes, set up brigades where your risk level calls for it, and run drills at the frequency the standard sets, documenting each one.
Common mistakes
- Extinguishers blocked by goods or with the sign covered.
- A single extinguisher type for areas with different risks.
- Inspections without a record, or records filled in without checking the equipment.
- Not replacing the extinguisher that was used or sent for recharge.
- No extinguisher inventory: nobody knows how many there are, where they are or when they expire.
Frequently asked questions
Which class of extinguisher do I need?
It depends on the materials you handle and the risk in each area. As a general rule, classes A (solids), B (flammable liquids and gases), C (energized electrical equipment) and D (combustible metals) are considered. A plant usually needs several types; it is best to define them with your fire risk analysis.
How often should an extinguisher be inspected?
A periodic visual check with a record is recommended, plus maintenance by qualified personnel at the frequency set by NOM-002-STPS-2010 and the manufacturer's instructions. Check the current text of the standard for exact intervals.
Can a used extinguisher be put back in place?
No. After any use, even partial, it must be recharged or replaced before returning to service.
IMS Global, your safety and maintenance partner
At IMS Global we supply safety and hygiene equipment (PPE) and maintenance consumables to plants in Tijuana and the border region, and we can help you source and restock what your safety program needs, with stock follow-up. If you are reviewing your fire prevention program, let us talk about what your plant requires.